False 2- way control valves type L1UP and L1IP with 2.2.03- D motor type MT40, Gun Metal, PN 16, DN 15 – 20 mmGB- 1 Characteristics Motor type MT40 • Three- point floating control, 24 V AC • Automatic stroke adjustment Motor type MT40A • For analogue control signal 2- 10 V or 4- 20 mA, 24 V AC • Automatic stroke adjustment Valves type L1UP and L1IP • Nominal pressure PN 16 • Regulating capability kvs > 50 • Single seatedkvr • Internal pack box • Logarithmic characteristic Applications MT40/ MT40A is a series of valve actua-tors intended for control valves type L1UP and L1IP. The valves type L1UP and L1IP are mainly used for controlling heating and cooling systems. Design The valve components - spindle, seats and cone - are made of stainless steel. The valve body is made of gun metal RG 5. The valve spindle thread connects Specifications - valve TypeConnection DN mm Opening mm kvs- value m3/ h Lifting height mm Max. ?p L bar Weight kg Type L1UP ( External connection threads ISO 228) 15 L1UPG ¾ 15152.7512140.7 20 L1UPG120205148.60.8 Type L1IP ( Internal connection threads ISO 7/ 1) 15 L1IPRp ½ 15152.7512140.7 20 L1IPRp ¾ 20205148.60.8 Pressure/ Temperature Diagram According to DIN 2401 Bar 16 15,5 11 0100130150225 o C Not to be used to motor MT40/ MT40A only. The valves are single seated and the leakage rate is less than 0.05% of the full flow ( accord-ing to VDI/ VDE 2174). The valve has a build- in pack box. Quality assurance All valves are manufactured under an ISO 9001 certification, and are pressure and leakage tested before shipment. Function The regulation capability of the valves are better that 50: 1. This means that the defined regulating characteristic will not cease, until the flow has dropped below 2% of full flow. L1UP and L1IP valves differ from other Clorius valves by having internal pack box. MT40 Actuator for three- point floating control signal ( increase- decrease). Supply voltage 24V AC. MT40A A microprocessor based actuator for a 2- 10 V or 4- 20 mA input signal. Supply voltage 24V AC. The actuator has auto-matic stroke adjustment. Subject to change without notice. Valve type L1UP/ L1IP Motor type MT40/ MT40A Clorius Controls A/ S Tempovej 27 · DK- 2750 Ballerup · Denmark Tel.: + 45 77 32 31 30 · Fax: + 45 77 32 31 31 E- mail: mail@ cloriuscontrols. com Web: www. cloriuscontrols. com

False GB- 2 2- way control valves type L1UP and L1IP with 2.2.03- D motor type MT40, Gun Metal, PN 16, DN 15 – 20 mm Definition of kvs- value The kvs- value is identical to the IEC flow coefficient kv and defined as the water flow rate in m3/ h through the fully open valve by a constant differential pressure, ?pv, of 1 bar. Mounting For valve temperatures of max. 170 º C, the motor can be fitted below or above the valve. Wiring and dimensions MT40 three- point 10 V AC 2Not connected 324 V AC ( stem up) 424 V AC ( stem down) MT40A 2- 10 V, 4- 20 mA control 10 V AC 224 V AC 32- 10 V DC 4 54- 20 mA ( feedback signal) Technical Data - motor Supply voltage 24 V AC Control signal 2- 10 V or 4- 20 mA. ( For 4- 20 mA control signal a 500 Ohms resistor ( enclosed in packing) is to be mounted between the control signal ( terminal 3) and system neutral ( terminal 1)). Transformer sizing 6 VA Stroke time MT40 3 or 1.5 s/ mm ( 3 s/ mm factory set) MT40A 3 s/ mm Force 400 N Ambient temperature - 18 - + 50 º C Storage temperature - 30 - + 50 º C Ambient humidity Max 90% RH Cable connection Screw terminals Degree of protection IP54 Weight 0.9 kg Technical Data - valve Materials: - Valve body Gun metal RG 5 - components Stainless steel Nominal pressure PN 16 Seating Single seated Valve characteristic Logarithmic Leakage = 0.05% of kvs Temperature range max. 150 º C Connection: - type L1UP External connec-tion threads ISO 228 - type L1IP Internal connec-tion threads ISO 7/ 1 Strainer It is recommended to use a strainer in front of the regulating valve if the liquid contains suspended particles. Accessories Pipe connectors for L1UP valves. Subject to change without notice. Type L mm H1 mm H mm ( w/ MT40) H mm ( w/ MT40A) L1 mm dB mm Type L1UP ( External connection threads ISO 228) 15 L1UP8520220250122G ¾ B92 20 L1UP9523225255122G1B92 Type L1IP ( Internal connection threads ISO 7/ 1) 15 L1IP8520220250122Rp ½ 92 20 L1IP9523225255122Rp ¾ 92 L L1 d H1H B Dimension Sketch Clorius Controls A/ S Tempovej 27 · DK- 2750 Ballerup · Denmark Tel.: + 45 77 32 31 30 · Fax: + 45 77 32 31 31 E- mail: mail@ cloriuscontrols. com Web: www. cloriuscontrols. com